Categories
Analog input device PAV - 3
ATS devices in networks 0.4 - 150 kV
Busbar coupler protection devices
Cabinets of relay protection and automation of series
Central annunciator units
Device discrete input/output DDIO
Device is intended for the reflection of the state of interconnect equipment
Device of arc protection of the PDZ
Devices for regulating the voltage of the transformer under load
Devices for the protection of the section
Discrete input devices DDI
Discrete output devices DDO
Disposing device DSH
Electric motor protection devices
Fiber Optic DVO Sensor
Hardware and software system promHMI
Input and output protection devices based on OCP
Input and output protection devices with directional earth fault protection
Input protection devices, busbar coupleres, outgoing lines and standby transformer protection
Input, output and standby protection devices for transformers
Line protection devices
Motor differencial protection devices of transformer
Power supply IP-02-MRZS
Voltage monitoring devices and voltage protection kit
MРЗС-05Л_м AИAР.466452.001-40
Used as protection of the feeder cable and overhead lines in networks with compensated and uncompensated capacitive currents. Directional ground-fault protection allows the device to be installed on connections that have a capacitive current of 40% or more of the capacitive current of the substation. It has a large number of service functions. Devices can be placed: in the relay compartments of single-end service assembled chambers, switchgears and control gears, outdoor switchgears (YAKNO), panels, in control cabinets.
Description
Performs the following functions:
Provides control and measurement of the following values:
- phase currents 1a, 1c, 1b (calculated) - from 0,1 to 30 Iн;
- zero sequence current - from 0.01 to 2 A;
- residual voltage 3Uo or Uab to - 150 B
- direct sequence current;
- negative sequence current.
Relay protection functions:
- four-stage overcurrent protection (OCP), has the following stages:
- 1 stage with definite time delay (current cut off);
- 2 stage with definite time delay or with a current definite time delay (in accordance with IES 255-4 types A, B, C, characteristics RТ-80, RТV-1);
- 3 stage with definite time delay or with a current definite time delay (in accordance with IES 255-4 types A, B, C, characteristics RТ-80, RТV-1);
- 4 stage with definite time delay (overload protection).
- blocking of the overcurrent protection from magnetizing-current inrush.
- two-stage directional ground fault protection GFP is triggered by a forward or reverse power direction.
- non-directional ground-fault protection according to 3Io can be of two versions:
- 1) protection reacts to the residual current of the industrial frequency 3Io (analogue of the relay PTZ-51);
- 2) protection by the sum of the residual harmonic currents.
- zero-phase-sequence voltage protection 3Uо (RNN).
- negative phase-sequence protection (NPSP), reacts to the ratio of the negative sequence current to the direct sequence current (phase failure monitoring (PFM)).
- external protection with the control of any current or voltage from the supplied to the device is triggered by a signal from a discrete input.
- circuit-breaker failure protection (CBFP) with current control: the breaker failure protection is initiated when the protection is tripped or disconnected. The breaker failure protection has two stages by response time.
- implementation of busbar protection scheme (BPS).
Automation functions:
- two-time recloser (AR). The AR is started from OCP. Provides the ability to block reclosing through a discrete input.
- circuit breaker control. The circuit breaker can be switched on and off both from the device and via a discrete input (pulsed). If there is a command to turn off the circuit breaker, the switch-on signal is blocked.
- acceleration of the overcurrent protection by the fact of switching on the circuit breaker or the forced setting of the second and third stages of the overcurrent protection to the accelerated mode.
- circuit breaker closing and opening circuits monitoring.
- control of the integrity of the switch-on coil.
- tripping coil of circuit breaker integrity control.
- control of the switching resource of the circuit breaker.
Defined functions, triggers and logical elements:
- number of defined functions - 8;
- number of detected triggers is 4, the state of the triggers is stored in non-volatile memory;
- logical elements AND, OR, NOT, EXCLUSIVE-OR.
Emergency registrar of oscillograms of currents with recording of discrete signals:
- parameterizable duration of pre-emergency and emergency recording.
- resolution of the recorder by analog signals - no more than 1.25 ms.
- total recording time - 90 s.
Discrete event recorder:
- 60 recent events,
- up to 54 records in each accident with a discreteness in time - 1 ms.
Short-circuit current auxiliary power supply. If the power supply of the device at the power input of 220 V (or 110 V) The device can be powered from current transformers of phases A and C. In this case, the magnitude of the current must be 4 A or more for one of the phases or for the total of two phases.
Binary inputs feeding from internal source - From the DIP output, two discrete inputs can be energized
Number of freely programmable inputs, outputs, indicators:
- discrete inputs - 6, with the possibility of autonomous power supply of a discrete input;
- discrete relay outputs - 7 (one of the outputs is a bistable relay), without and with memorization, implementation of the ShMS;
- LED indicators - 14, with and without memory.
Overall and connecting dimensions and recommended marking
Simplified connection diagram
WisiNet2 Setup Utility
Software Wisinet2 for МРЗС-05Л, МРЗС-05Д, MRZS
This manual is written only for Updating the program WiziNet 2
software WisiNet_2_user manual