Central annunciator units MRZS-O
The device is intended for the organization of central signaling systems at substations, stations, and industrial facilities equipped with microprocessor-based, electronic, or electromechanical relay protection and automation devices.
It performs the following functions:
- monitoring and recording of discrete input signals, including pulse signals;
- monitoring and recording of group signaling input signals;
- generation of discrete output signals;
- monitoring of audio-visual signaling status;
- receiving and displaying alarm and warning signals with or without time delay;
- visual indication of input states;
- control of sound signaling (up to seven sound signaling devices) with automatic acknowledgment capability;
- transmission of signals to group signaling;
- transmission of signals to external visual signaling devices, including flashing mode;
- communication with higher-level control, data transmission and reception of signals with the ability to affect internal logic, LEDs, relays, acknowledgment.
Number of inputs
- 28–56 freely programmable discrete inputs
- 0–4–8 inputs with current increment measurement for group signaling (GSS)
- 0–1–2 analog inputs for control of operating voltage value - operation by current in the device does not depend on voltage level (GSS operation by resistance).
Number of LEDs
- 60 freely programmable single-color
- 2 service three-color LEDs:
- device healthy/faulty status
- sound signaling operation
Number of discrete outputs – 9
- 7 relay outputs
- 2 power outputs
- all outputs freely programmable, including pulsing light relay
Buttons
- 3 service buttons: sound signaling off button “Silence”, indication reset button, LED test button
- 4 freely programmable buttons
- 6 navigation buttons
Free programmable logic
Interfaces: RS-485, USB, Ethernet (RJ-45 or optical ST);
Communication protocols: Modbus RTU, Modbus TCP, IEC 61850 (GOOSE, MMS), DNP3, IEC 60870-5-103, IEC 60870-5-104
Multilingual menu – supports 3 languages.
Software WisiNet_2 for МРЗС-05Л, МРЗС-05Д, MRZS
Please pay attention! Many new versions of devices have been added for corrective work, the program must save the /data folder (with your archives), delete the WisiNet2 installation program, download the archive from the website and install the Wisinet2 program and replace the new /data folder with your previous oneDownload Wisinet 2
If you have a version of the WisiNet_2 program higher than v.22.1, you can simply update the jar fileUpdate programm Wisinet 2 download